Boulevards & public spaces
Permanent service points for Saudi walkways, plazas and public-realm developments. Close the cover to return the surface to everyday use.
Explore P1 / P2 / P3Kent Stainless · Saudi project supply
Recessed, telescopic, event, broadcast and water units by Kent Stainless. Supplied by Green Home, Riyadh.
An in-ground power unit is a stainless-steel service box set flush with paving. It brings industrial sockets, data or water to the point of use and closes discreetly into the ground when unused.
Compare floor boxes and in-ground units
Manufactured by Kent Stainless, Ireland
The Kent range
Nine Kent Stainless families cover compact power, event infrastructure, broadcast and water. Start with the service your space needs.

P1 / Type 1
A compact recessed connection point for vendors and smaller outdoor service locations. A cable outlet allows closed-lid operation.
Confirm the socket layout and cover load class for the project.

Designed around the surface
Outdoor ground boxes with industrial sockets place the connection below the paving. Open the cover to access the service panel; use the approved cable outlet on models designed for closed-lid operation.
Bring power, data or water to a planned location in the landscape.
Closed-lid operation is model-dependent. Type 5 operates open.
The recessed cover accepts the selected infill for a discreet finish.
Reference specifications
Use this model guide for initial selection. Final dimensions, electrical configurations and load classes are confirmed against the project submittal.
| Model | Cover / frame | Connections & capacity | Typical use |
|---|---|---|---|
| P1Type 1KIGU-400/450 | 400 × 450 mm | Up to 2 sockets, 16A / 32AClosed-lid operation | Food vendors, performers, outside broadcast |
| P2Type 2KIGU-450/600 | 450 × 600 mm | 3–4 × 16A / 32A; or 2 sockets + 1–4 RJ45Closed-lid operation | Markets, exhibitions, CCTV / traffic control |
| P3Type 3Type 3 | 600 × 600 mm | 16A / 32A + RJ45; 63A subject to confirmationClosed-lid operation | Plazas, commercial developments |
| T4Type 4KIGU-760/600 | 760 × 600 mm reference; confirm bespoke size | Project-specific power, data and XLR layoutOperation depends on configuration | Events, entertainment zones |
| T5Type 5KIGUEB1200/1200 | 1200 × 1200 mm | 125A + 63A + 16A reference configurationOpen-lid operation only | Festivals, major venues |
| T6Type 6KIGUT600/600 | 600 × 600 mm | Up to 8 IP67 electrical sockets + 8 IP67 data points; maximum 192AOpen-position use; raised by turn handle or cordless drill | Arenas, large events, campuses and multi-operator spaces |
| T7Type 7Type 7 Mall Box | 440 × 550 mm family | Shallow installation; power + dataClosed-lid operation | Malls, public concourses |
| T8Type 8KIGUBB550/600 | 550 × 600 mm reference; confirm dimensions | Up to 28 audio / video / data / fibre connectionsClosed-lid operation | Broadcast and media zones |
| T9Type 9KIGPWU300/600/450 | 300 × 600 mm | Water connection; optional bib tap + drainageRecessed cover when unused | Coffee vendors, markets, hospitality |
Type 3 63A options, Type 4 dimensions and layout, Type 5 depth, and Type 7 / Type 8 overall dimensions require confirmation against the current approved drawing. IP67 applies to the selected electrical equipment; it does not certify the complete installed pit as waterproof.
Applications
In-ground services suit planned public spaces with recurring power, data or water needs. Applications shown are use cases, not claimed project installations.
Permanent service points for Saudi walkways, plazas and public-realm developments. Close the cover to return the surface to everyday use.
Explore P1 / P2 / P3Power and potable water for food-truck parks, coffee kiosks, Ramadan night markets, hotels, resorts and waterfront promenades.
Explore P1 / P2 / T9Recessed infrastructure for seasonal festivals, National Day and Eid celebrations, stadium fan zones and broadcast areas.
Explore T4 / T5 / T8Shallow power and data connections for indoor retail common areas where the available floor depth is limited.
Explore T7Project planning
A permanently supplied in-ground unit can reduce repeated generator hire, local engine noise and exhaust. It needs a suitable upstream electrical supply. Connection cables and backup-power planning still matter.
Designed into the venue for repeated use. The connection is already near the activity, helping reduce long temporary cable runs. Budget for the civil works, drainage and incoming supply.
Consider for recurring events and established public spaces.
Consider when permanent supply is unavailable or backup generation is needed. Assess hire, fuel, access, cable distribution and the event’s noise and exhaust requirements.
Compare whole-project costs; savings depend on use and site conditions.
The right choice depends on visibility, services, electrical demand and installation depth. Capacity and water options vary by manufacturer and model.
| Consideration | In-ground unit | Pop-up / retractable | Power bollard | Indoor floor box |
|---|---|---|---|---|
| When unused | Flush cover | Retracted below surface | Remains visible | Flush with indoor floor |
| Power demand | Up to 125A on selected models | Check selected model | Check selected model | Check indoor specification |
| Water | Dedicated Type 9 | Product-dependent | Product-dependent | Outside this category |
| Installation | Recess, ducts and drainage | Retraction depth required | Foundation and incoming services | Floor build-up / raised floor |
| Explore | Kent range ↗ | Specify project needs | Power pedestals ↗ | Indoor floor boxes ↗ |
Project checklist
Confirm the complete installation with the MEP consultant and Kent Stainless before ordering.
Confirm the project voltage, frequency, phase, socket ratings and protective devices together. The brief's 230/400 V, 60 Hz requirement needs project and manufacturer confirmation.
Select the cover class for pedestrian areas or service-vehicle routes. Reference FACTA / BS EN 124 and the approved installation detail; do not assume a universal drive-over rating.
Coordinate a drain connection and the available excavation depth with the civil design. Allow for the cable ducts, paving build-up and maintenance access.
For coastal projects in Jeddah or Khobar, confirm stainless-steel grade and finish. For exposed sites, confirm dust protection, drainage and maintenance requirements. IP67 is not an IP68 rating.
The consultant must confirm applicable SASO and SBC 401 requirements. No Saudi certification or project approval is claimed on this page.
Technical questions
From Saudi BOQ terminology to cover loading, these are the details to settle before selecting a unit.
An in-ground power unit is a recessed stainless-steel box installed flush with paving. It provides industrial power sockets and, on selected models, data, audio or water connections. The cover sits flush when the unit is not in use.
No. This page covers in-ground utility boxes for plazas, markets and events. Aircraft ground power units are a different equipment category used to supply parked aircraft.
Some Saudi project BOQs use GPU for an in-ground utility unit serving as a heavy-duty outdoor industrial floor box. The terms are not universal synonyms. Indoor industrial floor boxes may have different drainage, loading and installation requirements.
Green Home Trading Est. in Riyadh supplies Kent Stainless in-ground power and water units for Saudi projects. Use the contact page to request a model specification, catalogue or quotation.
The range includes 16A to 125A power configurations, depending on the model. Single- and three-phase sockets, RJ45 data, XLR audio, fibre and video options must be selected for the project. IP67 refers to the specified electrical panels or sockets, not a blanket rating for the whole pit.
A telescopic unit rises above the paving when services are needed and returns below the recessed cover when it is not in use. Kent T6 is intended for large events, arenas, campuses and multi-operator locations where open-position operation is acceptable.
The cover load class must match the installation location. Kent specifies covers to FACTA and BS EN 124 requirements. Confirm the selected load class and installation detail before placing a unit on a vehicle route.
Several models support closed-lid use through a cable outlet. This does not apply to every model. Kent Type 5 is used with its lid open and the specified cover plates in place.
Recessed covers can accept paving infill. Many outdoor models are designed for 60 mm paving; 80 mm or 100 mm options are available on some configurations. Confirm the paving build-up for the chosen model.
Kent Type 9 is a recessed potable water unit. A tap connection can be specified to suit the site. The water supply and drainage must be coordinated with the project design.
A permanently supplied in-ground unit can reduce repeated generator hire and local generator noise and exhaust. It still needs an upstream electrical supply and connection cables. It does not generate electricity or replace backup power.
The range includes grade 316 / 316L stainless-steel construction. Confirm the material and finish for the selected unit, particularly for coastal or other demanding environments.
Provide the model or application, cover size, available depth, socket ratings and phase, data or water requirements, project location, quantity and target delivery date. Add the BOQ or drawing reference when available.
Green Home is based in Riyadh and supplies projects across Saudi Arabia. Share the project location through the contact page so the team can confirm supply arrangements and timing for your requirement.
An in-ground power unit, ground socket box or outdoor industrial floor box describes a recessed service point in this context. A power pit or underfloor distributor is a broader term: confirm the fitted equipment. An event power box describes its use; a pop-up unit specifically describes a retractable mechanism.
Looking for indoor office floor boxes? Explore our indoor rangeGreen Home · Riyadh
Green Home Trading Est. is a Riyadh-based supplier of Kent Stainless in-ground power and water units in Saudi Arabia.
We support MEP consultants, electrical contractors, main contractors, developers, municipalities, event operators, hotel and resort operators, and procurement teams with project enquiries.
Sales contact: [email protected] · Riyadh, Saudi Arabia
In-ground utility selection answers
An in-ground unit is used when a public realm, market, event space or hospitality area needs power, data or water access without permanent above-ground equipment. Confirm the service layout, cover size, installation depth, load class and site environment before selection.
Discuss your requirementIt is a recessed service box installed flush with paving or finished ground, providing selected power, data, audio, video or water connections for outdoor spaces.
No. This range refers to in-ground utility boxes for public spaces, events and outdoor project services. Aircraft ground power equipment is a different product category.
Selected units can be configured for potable water or combined project services. The water supply, drainage and final connection layout must be coordinated with the site design.
The selected cover load class and installation detail must be appropriate for the location. Confirm this specifically before placing a unit on a vehicle route.
Provide the application, services required, socket ratings, cover size, available depth, paving build-up, location, quantity and drawing or BOQ reference.
We use essential storage to run this website. Optional analytics help us improve it. Privacy policy.